+974 4486 6115, +974 5059 4733 sales@celestialqatar.com

CAVICEL S.P.A – ITALY

[vc_row full_width=”stretch_row”][vc_column width=”1/3″][sliding_box image=”159″ title=”FIRECEL SR114H”][vc_column_text]FIRECEL SR114H
Silicone Insulation, Overall Screen, Solid and Stranded Conductor

[popup title=”DETAILS” padding=”0″ button=”1″]

FIRECEL SR114H
Silicone Insulation, Overall Screen, Solid and Stranded Conductor

STANDARD CABLE 300/500V
BS 5839-1:2013 Clause 26.2D
BS EN 50200:2006 (PH 30 – PH 60 – PH 120) 830°C fire and mechanical shocks
BS EN 50200:2006 + Annex E 830°C – 30 min. (15 min. fire and mechanical shocks + 15 min. fire mechanical shocks and water spray)
BS 6387:2013
Cat. C fire @ 950°C – 180 min
Cat. W fire and water @ 650°C – 15 + 15 min
Cat. Z fire and mechanical shocks @ 950°C – 15 min.

Cable construction
Conductors:   Plain annealed copper wire, solid class 1 or stranded class 2 according to  BS EN 60228.
Insulation:   High performance fire resistant silicone rubber type EI2 to BS EN 50363-1.
Cabling:   Insulated cores are cabled together.
Overall screen: Aluminium/polyester tape.

Circuit protective conductor or drain wire : Uninsulated tinned copper conductor of the same section and class as the insulated conductors in the 2-, 3- and 4-core cables. Drain wire of 0.5 mm2 tinned copper conductor is provided in cables with more than 4 conductors.

Outer sheath : LSZH thermoplastic material type LTS3 to BS 7655-6.1. Colour red or white (other colours on request).

Colour code up to 4 cores to HD 308
2 cores blue – brown
3 cores brown – black – grey
4 cores blue – brown – black – grey
7 cores* centre: brown
1st layer: brown – black – 4 cores white
12 cores* centre: brown – black – white
1st layer: brown – black – 7 cores white
19 cores* centre: brown
1st layer: brown – black – 4 cores white
2nd layer: brown – black – 10 cores white
(* on request the cores can be one colour only, identified by printed numbers)

Applications
FIRECEL SR 114H are primarily intended for general application.
Typical applications are:

■■BS 5839-1 for standard fire resistant cables in fire detection and fire alarm systems for building
■■BS 5839-8 for voice alarm systems
■■BS 5839-9 for emergency voice communication systems.
■■BS 5266-1 for emergency lighting of premises (PH60)
■■BS 8519 for fire-resistant control cable systems for life safety and fire-fighting application – Category 1

Operating temperature
-40°C to +90°C

Applicable Standards
Basic design BS 7629-1
Fire resistant BS 6387 (cat. C-W-Z)
BS EN 50200 (class PH30 – PH60 – PH120)
BS EN 50200 annex E (fire, mechanical shock and water spray)
Flame retardant BS EN 60332-1-2
BS EN 60332-3-24 cat. C
Acid gas emission BS EN 50267-2-1 amd. 2
Smoke density BS EN 61034-2

[/popup][/vc_column_text][/vc_column][vc_column width=”1/3″][sliding_box image=”159″ title=”FIRECEL SR114E”][vc_column_text]FIRECEL SR114E
Mica/Silicone Insulation, Overall Screen, Solid and Stranded Conductor

[popup title=”DETAILS” padding=”0″ button=”1″]

FIRECEL SR114E
Mica/Silicone Insulation, Overall Screen, Solid and Stranded Conductor

ENHANCED CABLE 300/500V
BS 5839-1:2013 Clause 26.2D
BS EN 50200:2006 (PH 30 – PH 60 – PH 120) 830°C fire and mechanical shocks
BS 8434-2:2003 +A2:2009 930°C – 120 min. (60 min. fire and mechanical shocks + 60 min. fire mechanical shocks and water spray)
BS 6387:2013
Cat. C fire @ 950°C – 180 min
Cat. W fire and water @ 650°C – 15 + 15 min
Cat. Z fire and mechanical shocks @ 950°C – 15 min.

Cable construction
Conductors:   Plain annealed copper wire, solid class 1 or stranded class 2 according to  BS EN 60228.
Insulation:   Mica/Glass Fire Resistant Tape covered by high performance fire resistant silicone rubber type EI2 to BS EN 50363-1.
Cabling:   Insulated cores are cabled together.
Overall screen: Aluminium/polyester tape.

Circuit protective conductor or drain wire : Uninsulated tinned copper conductor of the same section and class as the insulated conductors in the 2-, 3- and 4-core cables. Drain wire of 0.5 mm2 tinned copper conductor is provided in cables with more than 4 conductors.

Outer sheath : LSZH thermoplastic material type LTS3 to BS 7655-6.1. Colour red or white (other colours on request).

Colour code up to 4 cores to HD 308
2 cores blue – brown
3 cores brown – black – grey
4 cores blue – brown – black – grey
7 cores* centre: brown
1st layer: brown – black – 4 cores white
12 cores* centre: brown – black – white
1st layer: brown – black – 7 cores white
19 cores* centre: brown
1st layer: brown – black – 4 cores white
2nd layer: brown – black – 10 cores white
(* on request the cores can be one colour only, identified by printed numbers)

Applications
FIRECEL SR 114E are primarily intended for general application.
Typical applications are:

■■BS 5839-1 for standard fire resistant cables in fire detection and fire alarm systems for building
■■BS 5839-8 for voice alarm systems
■■BS 5839-9 for emergency voice communication systems.
■■BS 5266-1 for emergency lighting of premises (PH60)
■■BS 8519 for fire-resistant control cable systems for life safety and fire-fighting application – Category 1

Operating temperature
-40°C to +90°C

Applicable Standards
Basic design BS 7629-1
Fire resistant BS 6387 (cat. C-W-Z)
BS EN 50200 (class PH30 – PH60 – PH120)
BS EN 50200 annex E (fire, mechanical shock and water spray)
BS 8434-2 (120 Min)
Flame retardant BS EN 60332-1-2
BS EN 60332-3-24 cat. C
Acid gas emission BS EN 50267-2-1 amd. 2
Smoke density BS EN 61034-2

[/popup][/vc_column_text][/vc_column][vc_column width=”1/3″][sliding_box image=”160″ title=”SAS – Security & Alarm Safety Cables”][vc_column_text]Cavicel – SAS [Security and Alarm Safety Cables]

THE RIGHT RANGE OF CABLES FOR MODERN BUILDING INSTALLATIONS

Flexible solutions for commercial, residential and industrial applications

[popup title=”DETAILS” padding=”0″ button=”1″]

Cavicel – SAS [Security and Alarm Safety Cables]THE RIGHT RANGE OF CABLES FOR MODERN BUILDING INSTALLATIONS

Flexible solutions for commercial, residential and industrial applications

New complex and intelligent installations nowadays require an up-to-date technology in many buildings, either commercial or industrial. Specially for systems that supervise critical installations the designers have to consider very carefully all components to assure the best performance with reasonable price.

Security, Alarm, Sound application, computer network, CCTV is the installations that require these specific products. Cavicel with its SAS cable range gives the right answer for safe wiring of all these systems.

Quality, performance, compliance with standards, but we add more: SAFETY at any time. For this reason, the first choice we have done for this range of cables is the selection of materials that assure the best performance in case of a fire: LSZH – Low Smoke Zero Halogen

Fires have a high cost in terms of loss of human life and of damages to plants and structures.

About a third of fires originate inside buildings.
Research studies in this field state that the most commonly identified cause of death from a fire accident is being overcome by gas or smoke (Department for Communities and Local Government – formerly ODPM – Fire Statistics, United Kingdom, 2005).

Other influential sources have demonstrated that for the last 50 years, the average time from ignition of a fire to flashover has gone from 15 minutes to 3 minutes, thus seriously complicating the escape from fire. And this is due only to the increase of plastics in home and buildings.

It has to be kept into consideration, then, that even the most sophisticated alarm systems or emergency systems can be  useless if their performance is compromised by the destruction of the cables. This is the reason why, over the last few years, the companies have strongly invested in design and development of insulation material and cables providing the best performance and circuit integrity in case of fire, while reducing fumes and acid gases emission.

Cavicel has been present for years onto the market with its own products and its own experience.

Different constructions, different specifications, only one aim: SAFETY. Materials are properly selected in order to assure required electrical performance, but also to assure the best reaction in case of fire.

Cavicel Technical Department has all the know how to design the proper construction, and Cavicel Quality Control Department can verify not only traditional electrical characteristic but also the fire performance.

APPLICATIONS FOR
·  Airport
·  Data centres
·  Hospitals
·  Urban security
·  Public Buildings
·  Commercial Centres
·  Building automation
·  Fire Safety
·  Security
·  Energy efficiency
·  Low voltage systems
·  C.C.T.V.
·  F.A. systems
·  P.A. systems

[/popup]